Description
Altronix 8 fused outputs power supply/access power controller converts a 115V AC 60Hz input into 8 independently controlled 24V DC fail-safe and/or fail-secure outputs with a total of 10 amp continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an access control system, card reader, keypad, push button, PIR, etc. This unit will route power to a variety of access control hardware devices including mag locks, electric strikes, magnetic door holders, etc. The outputs will operate in both fail-safe and/or fail-secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or 2 totally independent power sources, 1 providing power for board operation and the other for lock/accessory power. The FACP interface enables emergency egress, alarm monitoring, or may be used to trigger other auxiliary devices. Input: Input 115V AC 60Hz rated at 4.4 amp. Power supply input options: 1) common power input for ACM8 and lock power (factory installed). 2 isolated power inputs - 1 to power the ACM8 and 1 for lock accessory power, (external power supply is required). 8 access control system trigger inputs. Output: 24V DC at 10 amp supply current, 8 independently controlled outputs. Normally open (NO) or normally closed (NC) dry contact input. Polarity reversal input from FACP signaling circuit. Alarm output relay indicates that FACP input is triggered (form "C" contact rated at 1 amp 28VDC not evaluated by UL). Operating temperature: 0 to 49 degree C ambient. ACM8 board main fuse is rated at 10 amp. BTU/Hr. 122.84BTU/Hr. Lifetime warranty. Measures 12-1/4-inches width by 15-1/2-inches height by 4-1/2-inches depth. 1.125-inches and 1.375-inches combination knockouts. UL listed, CSFM - California State Fire Marshal Approved, MEA - NYC Department of Buildings Approved.
Altronix ACM Series Access Power Controller with 8 Fused Outputs Power Supply, 24 VDC, 10 Amps (Pack of 1)
Price is below average
Current Price
$281.7
Average
$285.14
Min Price
$125.89
Max Price
$386.27
Price dynamics
1%
Description
Altronix 8 fused outputs power supply/access power controller converts a 115V AC 60Hz input into 8 independently controlled 24V DC fail-safe and/or fail-secure outputs with a total of 10 amp continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an access control system, card reader, keypad, push button, PIR, etc. This unit will route power to a variety of access control hardware devices including mag locks, electric strikes, magnetic door holders, etc. The outputs will operate in both fail-safe and/or fail-secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or 2 totally independent power sources, 1 providing power for board operation and the other for lock/accessory power. The FACP interface enables emergency egress, alarm monitoring, or may be used to trigger other auxiliary devices. Input: Input 115V AC 60Hz rated at 4.4 amp. Power supply input options: 1) common power input for ACM8 and lock power (factory installed). 2 isolated power inputs - 1 to power the ACM8 and 1 for lock accessory power, (external power supply is required). 8 access control system trigger inputs. Output: 24V DC at 10 amp supply current, 8 independently controlled outputs. Normally open (NO) or normally closed (NC) dry contact input. Polarity reversal input from FACP signaling circuit. Alarm output relay indicates that FACP input is triggered (form "C" contact rated at 1 amp 28VDC not evaluated by UL). Operating temperature: 0 to 49 degree C ambient. ACM8 board main fuse is rated at 10 amp. BTU/Hr. 122.84BTU/Hr. Lifetime warranty. Measures 12-1/4-inches width by 15-1/2-inches height by 4-1/2-inches depth. 1.125-inches and 1.375-inches combination knockouts. UL listed, CSFM - California State Fire Marshal Approved, MEA - NYC Department of Buildings Approved.
Price will be lower
in next 2 weeks
in next 2 weeks
According to the data, price will be lower in next two weeks, so not waste your money and track better price!
Product review & video
[Music] everybody dug here and welcome back to our continuing series of videos for the kid FX conventional line of panels in this video we will show you how to connect a booster power supply to your FX 5 or FX 10 conventional panel when your installation requires additional nak circuits using Genesis horn strips the FX 5 control panel nak circuits will provide up to 2 amps each with a maximum of 3 point 5 amps total the FX 10 panel can provide 2 amps for each nak circuit with a maximum of 7 amps total for larger installations where multiple nak circuits are necessary or the number of nak circuits will exceed the amperage draw of the FX 5 or FX 10 panel the use of a VPS 6a or VPS 10a will be necessary this figure shows the specifications for both versions of booster panel the bps can be configured a few different ways in this video we will show you how to configure and wire the VPS panel


Similar products
