Description
Input: 120VAC 60Hz, 7.0 amp input. Power supply input options: a) Two (2) common power input for either ACM8 and lock power (factory installed). b) Two (2) isolated power inputs (external power supply is required). Current is determined by the power supply connected, not to exceed a maximum of 10 amp total. Sixteen (16) Access Control System trigger inputs. Input options: a) Sixteen (16) normally open (NO) inputs. b) Sixteen (16) open collector inputs. c) Any combination of the above. Output: 12VDC and/or 24VDC outputs. Maximum output current: Options: a) 12VDC @ 5.3 amp plus 12VDC @ 5.3 amp b) 12VDC @ 5.3 amp plus 24VDC @ 5.6 amp c) 24VDC @ 5.6 amp plus 24VDC @ 5.6 amp Non power-limited outputs. Sixteen (16) independently controlled outputs. Output options: a) Sixteen (16) Fail-Safe and/or Fail-Secure power outputs. b) Sixteen (16) form C 5 amp rated relay outputs. c) Any combination of the above. Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2.5 amp). Filtered and electronically regulated outputs (built-in power supply). Thermal and short circuit protection with auto reset. Fuse Ratings: Power Supply input fuse rated @ 5 amp/250V. ACM8 boards main fuse is rated at 10 amp. Fused outputs are rated @ 2.5 amp each. Supervision: AC fail supervision (form C contacts). - Notification trigger is selectable for 30 seconds (factory set) or 2 hours. Battery fail and presence supervision (form C contacts). Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge. Features: Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs. Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit. Alarm output relay indicates that FACP input is triggered
Altronix MAXIMAL33F
Price is below average
Current Price
$754.05
Average
$766.06
Min Price
$500
Max Price
$834.17
Price dynamics
2%
Description
Input: 120VAC 60Hz, 7.0 amp input. Power supply input options: a) Two (2) common power input for either ACM8 and lock power (factory installed). b) Two (2) isolated power inputs (external power supply is required). Current is determined by the power supply connected, not to exceed a maximum of 10 amp total. Sixteen (16) Access Control System trigger inputs. Input options: a) Sixteen (16) normally open (NO) inputs. b) Sixteen (16) open collector inputs. c) Any combination of the above. Output: 12VDC and/or 24VDC outputs. Maximum output current: Options: a) 12VDC @ 5.3 amp plus 12VDC @ 5.3 amp b) 12VDC @ 5.3 amp plus 24VDC @ 5.6 amp c) 24VDC @ 5.6 amp plus 24VDC @ 5.6 amp Non power-limited outputs. Sixteen (16) independently controlled outputs. Output options: a) Sixteen (16) Fail-Safe and/or Fail-Secure power outputs. b) Sixteen (16) form C 5 amp rated relay outputs. c) Any combination of the above. Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2.5 amp). Filtered and electronically regulated outputs (built-in power supply). Thermal and short circuit protection with auto reset. Fuse Ratings: Power Supply input fuse rated @ 5 amp/250V. ACM8 boards main fuse is rated at 10 amp. Fused outputs are rated @ 2.5 amp each. Supervision: AC fail supervision (form C contacts). - Notification trigger is selectable for 30 seconds (factory set) or 2 hours. Battery fail and presence supervision (form C contacts). Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge. Features: Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs. Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit. Alarm output relay indicates that FACP input is triggered
Price will be lower
in next 2 weeks
in next 2 weeks
According to the data, price will be lower in next two weeks, so not waste your money and track better price!
Similar products
